Pompage par siphon en fonctionnement

Siphon Pumping

Scaling and pumping by siphon to supply a backwater of the Rhône from the Jonage Canal

Context

Project Type :

Pumping Solutions

Location :

Grand Parc – Miribel Jonage (69)
Logo entreprise Artelia Logo entreprise SPL Segapal Logo entreprise Vinci Construction

Problem

  • The customer asked us to scale a siphon to supply a backwater of the Rhône from the Jonage Canal managed by EDF: flow, water head, length of conduit and longitudinal section were given to us
  • We had to provide the design note for the scaling, supervise the company that undertook the installation work, then provide operating tests and commissioning
  • Once the siphon was received, providing a complete priming assembly so that the organisation was autonomous to initiate their conduits according to their requirements

Solution

Scaling 5 conduits of nominal diameter 400 mm with elbows and accessories:

  • Total flow rate: 2 m³/s
  • Water head: 3.76 m
  • Length of conduit: 65 m
  • Complete priming assembly sold:
    • A vacuum pump 2.2 kW + accessories
    • A generator 17 kVA
    • A double-axle trailer
5 conduites en DN 400 mm
Ensemble complet d'amorçage
Pompage par siphon en route